Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

The Design and Construction of the MICE Spectrometer Solenoids

Journal Article · · IEEE Transactions on Applied Superconductivity
OSTI ID:948479

The purpose of the MICE spectrometer solenoid is to provide a uniform field for a scintillating fiber tracker. The uniform field is produced by a long center coil and two short end coils. Together, they produce 4T field with a uniformity of better than 1% over a detector region of 1000 mm long and 300 mm in diameter. Throughout most of the detector region, the field uniformity is better than 0.3%. In addition to the uniform field coils, we have two match coils. These two coils can be independently adjusted to match uniform field region to the focusing coil field. The coil package length is 2544 mm. We present the spectrometer solenoid cold mass design, the powering and quench protection circuits, and the cryogenic cooling system based on using three cryocoolers with re-condensers.

Research Organization:
Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (US)
Sponsoring Organization:
Accelerator& Fusion Research Division; Engineering Division
DOE Contract Number:
AC02-05CH11231
OSTI ID:
948479
Report Number(s):
LBNL-1506E
Journal Information:
IEEE Transactions on Applied Superconductivity, Journal Name: IEEE Transactions on Applied Superconductivity Journal Issue: 3 Vol. 19
Country of Publication:
United States
Language:
English

Similar Records

Progress on the MICE Tracker Solenoid
Conference · Sat Jun 10 00:00:00 EDT 2006 · OSTI ID:918620

Fabrication, Testing and Modeling of the MICE Superconducting Spectrometer Solenoids
Conference · Sun May 16 00:00:00 EDT 2010 · OSTI ID:986203

The Design Parameters for the MICE Tracker Solenoid
Journal Article · Sun Aug 20 00:00:00 EDT 2006 · IEEE Transactions on Applied Superconductivity · OSTI ID:918476