The Use of Energy Information in Plastic Scintillator Material
Journal Article
·
· Journal of Radioanalytical and Nuclear Chemistry, 276(3):743-748
Plastic scintillator material is often used for gamma-ray detection in many applications due to its relatively good sensitivity and cost-effectiveness compared to other detection materials. However, due to the dominant Compton scattering interaction mechanism, full energy peaks are not observed in plastic scintillator spectra and isotopic identification is impossible. Typically plastic scintillator detectors are solely gross count detectors. In some safeguards and security applications, such as radiation portal monitors for vehicle screening, naturally-occurring radioactive material (NORM) often triggers radiation alarms and results in innocent or nuisance alarms. The limited energy information from plastic scintillator material can be used to discriminate the NORM from targeted materials and reduce the nuisance alarm rate. An overview of the utilization of the energy information from plastic scintillator material will be presented, with emphasis on the detection capabilities and potential limitations for safeguards and security applications. (PIET-43741-TM-490)
- Research Organization:
- Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-76RL01830
- OSTI ID:
- 947903
- Report Number(s):
- PNNL-SA-49297; 400904120
- Journal Information:
- Journal of Radioanalytical and Nuclear Chemistry, 276(3):743-748, Journal Name: Journal of Radioanalytical and Nuclear Chemistry, 276(3):743-748 Journal Issue: 3 Vol. 276; ISSN JRNCDM; ISSN 0236-5731
- Country of Publication:
- United States
- Language:
- English
Similar Records
The Use of Energy Windowing to Discriminate SNM from NORM in Radiation Portal Monitors
Field Tests of a NaI(Tl)-Based Vehicle Portal Monitor at Border Crossings
Discrimination of Naturally Occurring Radioactive Material in Plastic Scintillator Material
Journal Article
·
Wed May 10 00:00:00 EDT 2006
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, 560(2):373-387
·
OSTI ID:882374
Field Tests of a NaI(Tl)-Based Vehicle Portal Monitor at Border Crossings
Conference
·
Fri Oct 01 00:00:00 EDT 2004
·
OSTI ID:889093
Discrimination of Naturally Occurring Radioactive Material in Plastic Scintillator Material
Conference
·
Tue Aug 19 00:00:00 EDT 2003
·
OSTI ID:969624