The Tevatron Chromaticity tracker

Technical Report ·
DOI:https://doi.org/10.2172/946542· OSTI ID:946542

The Tevatron chromaticity tracker (CT) has been successfully commissioned and is now operational. The basic idea behind the CT is that when the phase of the Tevatron RF is slowly modulated, the beam momentum is also modulated. This momentum modulation is coupled transversely via chromaticity to manifest as a phase modulation on the betatron tune. Thus by phase demodulating the betatron tune, the chromaticity can be recovered. However, for the phase demodulation to be successful, it is critical that the betatron tune be a coherent signal that can be easily picked up by a phase detector. This is easily done because the Tevatron has a phase locked loop (PLL) based tune tracker which coherently excites the beam at the betatron tune.

Research Organization:
Fermi National Accelerator Laboratory (FNAL), Batavia, IL
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-07CH11359
OSTI ID:
946542
Report Number(s):
FERMILAB-TM-2422-AD
Country of Publication:
United States
Language:
English

Similar Records

Chromaticity tracking with a phase modulation/demodulation technique in the Tevatron
Journal Article · Wed Dec 31 23:00:00 EST 2008 · Nucl.Instrum.Meth.A602:352-356,2009 · OSTI ID:948161

Preliminary studies of a chromaticity tracker
Technical Report · Tue Feb 28 23:00:00 EST 2006 · OSTI ID:891085

Preliminary Studies of a Phase Modulation Technique for Measuring Chromaticity
Conference · Fri Mar 31 23:00:00 EST 2006 · AIP Conf.Proc.868:508-516,2006 · OSTI ID:892276