Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Report of tritide study at the Responsive Neutron Generator Product Deployment Center.

Technical Report ·
DOI:https://doi.org/10.2172/945190· OSTI ID:945190

This report documents a study of sample counting results for wipes from routine surface area monitoring conducted at the Responsive Neutron Generator Product Deployment Center (RNGPDC) at Sandia National Laboratories (SNL). The study was initiated in November 2006, with two samples suspected of containing erbium tritide, after some samples were found to exhibit higher tritium counting rates upon recount at a later time. The main goal of the study was to determine whether the current practice of analyzing tritium wipe samples once, within a few days of sample collection, is adequate to accurately quantify the amount of tritium on the sample when tritides may be present. Recommendations are made toward routine recounting of vials suspected of containing particulate forms of tritium.

Research Organization:
Sandia National Laboratories
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
945190
Report Number(s):
SAND2008-7583
Country of Publication:
United States
Language:
English

Similar Records

Summary of Sandia research on metal tritides : FY 2007.
Technical Report · Thu May 01 00:00:00 EDT 2008 · OSTI ID:974412

Metal tritides helium emission
Technical Report · Thu Jan 31 23:00:00 EST 1980 · OSTI ID:5551079

Room temperature desorption of helium-3 from metal tritides. [Er tritide]