Remaining Sites Verification Package for the 116-F-8, 1904-F Outfall Structure and the 100-F-42, 1904-F Spillway, Waste Site Reclassification Form 2006-045
The 100-F-42 waste site is the portion of the former emergency overflow spillway for the 1904-F Outfall Structure formerly existing above the ordinary high water mark of the Columbia River. The spillway consisted of a concrete flume designed to discharge effluent from the 107-F Retention Basin in the event that flows could not be completely discharged via the river outfall pipelines. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.
- Research Organization:
- Washington Closure Hanford
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC06-05RL14655
- OSTI ID:
- 944421
- Report Number(s):
- RSVP-2006-045
- Country of Publication:
- United States
- Language:
- English
Similar Records
Remaining Sites Verification Package for the 116-F-8, 1904-F Outfall Structure and the 100-F-42, 1904-F Spillway, Waste Site Reclassification Form 2006-038
Remaining Sites Verification Package for the 116-F-16, PNL Outfall and the 100-F-43, PNL Outfall Spillway, Waste Site Reclassification Form 2006-046
Remaining Sites Verification Package for the 116-F-16, PNL Outfall and the 100-F-43, PNL Outfall Spillway, Waste Site Reclassification Form 2006-039
Technical Report
·
Mon Sep 25 00:00:00 EDT 2006
·
OSTI ID:944423
Remaining Sites Verification Package for the 116-F-16, PNL Outfall and the 100-F-43, PNL Outfall Spillway, Waste Site Reclassification Form 2006-046
Technical Report
·
Thu Sep 14 00:00:00 EDT 2006
·
OSTI ID:944441
Remaining Sites Verification Package for the 116-F-16, PNL Outfall and the 100-F-43, PNL Outfall Spillway, Waste Site Reclassification Form 2006-039
Technical Report
·
Thu Sep 14 00:00:00 EDT 2006
·
OSTI ID:944440
Related Subjects
100-F-42 waste site
100F Area
107-F Retention Basin
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
1904-F Outfall Structure
54 ENVIRONMENTAL SCIENCES
COLUMBIA RIVER
CONCRETES
Columbia River
Hanford
PIPELINES
RETENTION
RIVERS
SAMPLING
SOILS
SPILLWAYS
VERIFICATION
WASTES
WATER
concrete flume
100F Area
107-F Retention Basin
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
1904-F Outfall Structure
54 ENVIRONMENTAL SCIENCES
COLUMBIA RIVER
CONCRETES
Columbia River
Hanford
PIPELINES
RETENTION
RIVERS
SAMPLING
SOILS
SPILLWAYS
VERIFICATION
WASTES
WATER
concrete flume