Insertion Devices for NSLS-II Baseline and Future
NSLS-II is going to employ Damping Wigglers (DWs) not only for emittance reduction but also as broad band hard X-ray source. In-Vacuum Undulators (IVUs) with the minimum RMS phase error (< 2 degree) and possible cryo-capability are planned for X-ray planar device. Elliptically Polarized Undulators (EPUs) are envisioned for polarization controls. Due to the lack of hard X-ray flux from weak dipole magnet field (0.4 Tesla), three pole wigglers (3PWs) of the peak field over 1 Tesla will be mainly used by NSLS bending magnet beam line users. Magnetic designs and kick maps for dynamic aperture surveys were created using the latest version of Radia [1] for Mathematica 6 which we supported the development. There are other devices planned for the later stage of the project, such as quasi-periodic EPU, superconducting wiggler/undulator, and Cryo-Permanent Magnet Undulator (CPMU) with Praseodymium Iron Boron (PrFeB) magnets and textured Dysprosium poles. For R&D, Hybrid PrFeB arrays were planned to be assembled and field-measured at room temperature, liquid nitrogen and liquid helium temperature using our vertical test facility. We have also developed a specialized power supply for pulsed wire measurement.
- Research Organization:
- Brookhaven National Laboratory
- Sponsoring Organization:
- Doe - Office Of Science
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 941616
- Report Number(s):
- BNL--81642-2008-CP; 39KC02000
- Country of Publication:
- United States
- Language:
- English
Similar Records
INSERTION DEVICE ACTIVITIES FOR NSLS-II.
INSERTION DEVICES R AND Ds FOR NSLS-II.