With the continued population of the International Monitoring System (IMS) network and the certification of radioxenon laboratory systems it has become necessary to calibrate and test these systems using as many of the radioxenon isotopes as possible. Several very promising techniques have been explored recently that allow for convenient production of Xe-133, Xe-131m, the short-lived isotope Xe-135, and even the difficult to obtain Xe-133m. IMS national and international laboratories have traditionally obtained Xe-133 from medical isotope suppliers. The activity of these medical dose samples is extremely high (~ 740 MBq) and requires very careful fume hood work to dilute down to appropriate levels (~ 10 Bq). By waiting for 10 or more half-lives it is possible to reduce the handling regimen considerably, while also obtaining a strong Xe-131m signature due to its longer half-life (11.9 days). The short-lived isotope Xe-135 (9.14 hrs) and the longer lived parent nuclide Xe-133m (2.2 day half-life) are never present in these samples. To obtain these isotopes another source or technique is required. This paper will discuss the two techniques developed and implemented at Pacific Northwest National Lab (PNNL) and show the results obtained from each technique. The first is an in-house method that allows for on demand production of two of these isotopes, Xe-133 and Xe-135, using HEU and a modest flux neutron source. The second method uses a research reactor at the Pullman campus of Washington State University to produce Xe-133, Xe-133m and Xe-135.
- Research Organization:
- Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-76RL01830
- OSTI ID:
- 939033
- Report Number(s):
- PNNL-SA-61802; NN2003000
- Country of Publication:
- United States
- Language:
- English
Similar Records
Testing of the KRI-developed Silicon PIN Radioxenon Detector
Coincidence measurements of radioxenon using passive implemented planar silicon (PIPS) detector
A prototype detection system for atmospheric monitoring of xenon radioisotopes
Technical Report
·
Thu Jan 22 23:00:00 EST 2015
·
OSTI ID:1258733
Coincidence measurements of radioxenon using passive implemented planar silicon (PIPS) detector
Journal Article
·
Wed Sep 14 20:00:00 EDT 2022
· Journal of Radioanalytical and Nuclear Chemistry
·
OSTI ID:1878083
A prototype detection system for atmospheric monitoring of xenon radioisotopes
Journal Article
·
Sun Nov 05 19:00:00 EST 2017
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1454829