RELAP5 Analysis of the Hybrid Loop-Pool Design for Sodium Cooled Fast Reactors
Conference
·
OSTI ID:935457
An innovative hybrid loop-pool design for sodium cooled fast reactors (SFR-Hybrid) has been recently proposed. This design takes advantage of the inherent safety of a pool design and the compactness of a loop design to improve economics and safety of SFRs. In the hybrid loop-pool design, primary loops are formed by connecting the reactor outlet plenum (hot pool), intermediate heat exchangers (IHX), primary pumps and the reactor inlet plenum with pipes. The primary loops are immersed in the cold pool (buffer pool). Passive safety systems -- modular Pool Reactor Auxiliary Cooling Systems (PRACS) – are added to transfer decay heat from the primary system to the buffer pool during loss of forced circulation (LOFC) transients. The primary systems and the buffer pool are thermally coupled by the PRACS, which is composed of PRACS heat exchangers (PHX), fluidic diodes and connecting pipes. Fluidic diodes are simple, passive devices that provide large flow resistance in one direction and small flow resistance in reverse direction. Direct reactor auxiliary cooling system (DRACS) heat exchangers (DHX) are immersed in the cold pool to transfer decay heat to the environment by natural circulation. To prove the design concepts, especially how the passive safety systems behave during transients such as LOFC with scram, a RELAP5-3D model for the hybrid loop-pool design was developed. The simulations were done for both steady-state and transient conditions. This paper presents the details of RELAP5-3D analysis as well as the calculated thermal response during LOFC with scram. The 250 MW thermal power conventional pool type design of GNEP’s Advanced Burner Test Reactor (ABTR) developed by Argonne National Laboratory was used as the reference reactor core and primary loop design. The reactor inlet temperature is 355 °C and the outlet temperature is 510 °C. The core design is the same as that for ABTR. The steady state buffer pool temperature is the same as the reactor inlet temperature. The peak cladding, hot pool, cold pool and reactor inlet temperatures were calculated during LOFC. The results indicate that there are two phases during LOFC transient – the initial thermal equilibration phase and the long term decay heat removal phase. The initial thermal equilibration phase occurs over a few hundred seconds, as the system adjusts from forced circulation to natural circulation flow. Subsequently, during long-term heat removal phase all temperatures evolve very slowly due to the large thermal inertia of the primary and buffer pool systems. The results clearly show that passive safety PRACS can effectively transfer decay heat from the primary system to the buffer pool by natural circulation. The DRACS system in turn can effectively transfer the decay heat to the environment.
- Research Organization:
- Idaho National Laboratory (INL)
- Sponsoring Organization:
- DOE - NE
- DOE Contract Number:
- AC07-99ID13727
- OSTI ID:
- 935457
- Report Number(s):
- INL/CON-07-13359
- Country of Publication:
- United States
- Language:
- English
Similar Records
Thermal Response of the Hybrid Loop-Pool Design for Sodium Cooled Faster Reactors
Study of thermal-hydraulic characteristics during decay heat removal in a pool-type fast breeder reactor
Design Considerations for Economically Competitive Sodium Cooled Fast Reactors
Conference
·
Mon Sep 01 00:00:00 EDT 2008
·
OSTI ID:941748
Study of thermal-hydraulic characteristics during decay heat removal in a pool-type fast breeder reactor
Journal Article
·
Tue Mar 31 23:00:00 EST 1992
· Nuclear Technology; (United States)
·
OSTI ID:5534620
Design Considerations for Economically Competitive Sodium Cooled Fast Reactors
Conference
·
Fri May 01 00:00:00 EDT 2009
·
OSTI ID:957556