Radiation shielding for the Main Injector collimation system
Conference
·
OSTI ID:932864
The results of Monte Carlo radiation shielding studies performed with the MARS15 code for the Main Injector collimation system at Fermilab are presented and discussed. MAD-to-MARS Beam Line Builder is used to generate realistic extended curvilinear geometry models.
- Research Organization:
- Fermi National Accelerator Laboratory (FNAL), Batavia, IL
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 932864
- Report Number(s):
- FERMILAB-CONF-08-146-APC
- Country of Publication:
- United States
- Language:
- English