Title: Biofiltration of Asphalt Emissions: Full-scale Operation Treating Off-gases from Polymer-modified Asphalt Production

Journal Article · · Environmental Progress
OSTI ID:932240

In response to complaints from nearby residents, a biofilter was designed, installed, and tested for treating odors in one of three odorous emission streams from an asphalt plant producing polymer-modified asphalt. Hydrogen sulfide (H2S) was determined to be the most prevalent gaseous reduced sulfur compound and was detected in the emission stream only when polymer material was being added to raw asphalt. Emission stream H2S concentrations we requite variable, ranging from 16 to approximately 30,000 ppm (v/v) and considered the likely compound contributing most to the plant's odor complaints. The biofilter was effective in controlling odor from the production process and removed an overall average of 65% of the H2S during polymer addition, and for H2S concentrations less than 400 ppmv, re m oval averaged 98%. These removal efficiencies reflect data from the biofilter operating at 2.5-minute empty bed residence time in 1996 and a 6.1-minute empty bed residence time in 1997. The biofilter's bed became increasingly acidified during the plant's 1997 operating season producing a pH gradient through the bed ranging from a high of 6.6 to a low of 3.1. The bed medium moisture content remained constant at about 60% (wet weight basis), but changes were observed in the water potential: no correlation to performance was determined. Changes in the microbial community reflected the bed acidification trend, with acidophiles becoming gene rally more numerous in the bed's deeper portions and in the mid to late season when the bed was most acidified. Bed acidification did not impact the biofilter's H2S removal efficiency. Nearby residents we resurveyed and roughly half of the respondents indicated that the odor conditions had improved, one-third felt odor conditions were unchanged and the remaining 15% felt odor conditions were worse despite the fact that only one of three of the plant's odorous emission streams were treated by the biofilter. Plans are to implement biofiltration for odor control at all of the facility's emission points.

Research Organization:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
DE-AC07-99ID-13727
OSTI ID:
932240
Report Number(s):
INEEL/JOU-98-00884; ENVPDI; TRN: US200812%%672
Journal Information:
Environmental Progress, Vol. 18, Issue 3; ISSN 0278-4491
Country of Publication:
United States
Language:
English