Compatibility Issues for a High Temperature Dual Coolant Blanket
- ORNL
One proposed U.S. test blanket module (TBM) for ITER uses ferritic-martensitic alloys with both eutectic Pb-Li and He coolants at {approx}475 C. In order for this blanket concept to operate at higher temperatures ({approx}750 C) for a DEMO-type reactor, several Pb-Li compatibility issues need to be addressed. A SiC/SiC composite flow channel insert is proposed to reduce the steel dissolution rate (and the magnetohydrodynamic pressure drop). Prior capsule testing examined dense, high-purity SiC in Pb-Li at 800-1200 C and found detectable levels of Si in the Pb-Li after 2,000h at 1100 C and 1,000h at 1200 C. Current capsule experiments are examining several different SiC/SiC composite materials at 1000 C. Another issue involves Pb-Li transport between the first wall and heat exchanger. Aluminide coatings on type 316 stainless steel and Al-containing alloys capable of forming an external alumina scale have been studied in capsule experiments at 700 and 800 C for 1,000h. Model aluminide coatings made by chemical vapor deposition reduced the dissolution rate for 316SS at 800 C by a factor of 50.
- Research Organization:
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC)
- DOE Contract Number:
- DE-AC05-00OR22725
- OSTI ID:
- 931974
- Resource Relation:
- Conference: ANS 17th Topical Meeting on Fusion Energy, Albuquerque, NM, USA, 20061113, 20061115
- Country of Publication:
- United States
- Language:
- English