Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Sensitive electrochemical immunoassay for 2,4,6-trinitrotoluene based on functionalized silica nanoparticle labels

Journal Article · · Analytica Chimica Acta, 610(1):112-118

We present a poly(guanine)-functionalized silica nanoparticle (NP) label-based electrochemical immunoassay for sensitively detecting 2,4,6-trinitrotoluene (TNT). This immunoassay takes advantage of magnetic bead–based platform for competitive displacement immunoreactions and separation, and use electroactive nanoparticles as labels for signal amplification. For this assay, anti-TNT-coated magnetic beads interacted with TNT analog-conjugated poly(guanine)-silica NPs and formed analog-anti-TNT immunocomplexes on magnetic beads. The immunocomplexes coated magnetic beads were exposed to TNT samples, which resulted in displacing the analog conjugated poly(guanine) silica NPs into solution by TNT. In contrast, there are no guanine residues releasing into the solution in the absence of TNT. The reaction solution was then separated from the magnetic beads and transferred to the electrode surface for electrochemical measurements of guanine oxidation with Ru(bpy)32+ as mediator. The sensitivity of this TNT assay was greatly enhanced through dual signal amplifications: 1) a large amount of guanine residues on silica nanoparticles is introduced into the test solution by displacement immunoreactions and 2) a Ru(bpy)32+-induced guanine catalytic oxidation further enhances the electrochemical signal. Some experimental parameters for the nanoparticle label-based electrochemical immunoassay were studied and the performance of this assay was evaluated. The method is found to be very sensitive and the detection limit of this assay is ~ 0.1 ng mL-1 TNT. The electrochemical immunoassay based on the poly[guanine]-functionalized silica NP label offers a new approach for sensitive detection of explosives.

Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US), Environmental Molecular Sciences Laboratory (EMSL)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
924672
Report Number(s):
PNNL-SA-53440; 17505; 12490
Journal Information:
Analytica Chimica Acta, 610(1):112-118, Journal Name: Analytica Chimica Acta, 610(1):112-118 Journal Issue: 1 Vol. 610; ISSN ACACAM; ISSN 0003-2670
Country of Publication:
United States
Language:
English

Similar Records

Electrochemical Immunoassay of Carcinoembryonic Antigen Based on A Lead Sulfide Nanoparticle Label
Journal Article · Wed Oct 01 00:00:00 EDT 2008 · Nanotechnology, 19(43):Art. No. 435501 · OSTI ID:946657

Sensitive Immunoassay of a Biomarker Tumor Necrosis Factor-[alpha] Based on Poly(guanine)-Functionalized Silica Nanoparticle Label
Journal Article · Sun Oct 01 00:00:00 EDT 2006 · Analytical Chemistry, 78(19):6974-6979 · OSTI ID:893245

Quantum-Dots Based Electrochemical Immunoassay of Interleukin-1α
Journal Article · Sun Jul 01 00:00:00 EDT 2007 · Electrochemistry Communications, 9(7):1573-1577 · OSTI ID:909681