Radiation monitoring with CVD Diamonds and PIN Diodes at BaBar
Journal Article
·
· Nucl.Instrum.Meth.A583:162-164,2007
OSTI ID:923767
The BaBar experiment at the Stanford Linear Accelerator Center has been using two polycrystalline chemical vapor deposition (pCVD) diamonds and 12 silicon PIN diodes for radiation monitoring and protection of the Silicon Vertex Tracker (SVT). We have used the pCVD diamonds for more than 3 years, and the PIN diodes for 7 years. We will describe the SVT and SVT radiation monitoring system as well as the operational difficulties and radiation damage effects on the PIN diodes and pCVD diamonds in a high-energy physics environment.
- Research Organization:
- Stanford Linear Accelerator Center (SLAC)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC02-76SF00515;
- OSTI ID:
- 923767
- Report Number(s):
- SLAC-PUB-13127
- Journal Information:
- Nucl.Instrum.Meth.A583:162-164,2007, Journal Name: Nucl.Instrum.Meth.A583:162-164,2007 Journal Issue: 1 Vol. 583; ISSN NIMAER; ISSN 0168-9002
- Country of Publication:
- United States
- Language:
- English