SUMP MEASURING SYSTEM
Conference
·
OSTI ID:921681
The process sumps in H-Canyon at the Savannah River Site (SRS) collect leaks from process tanks and jumpers. To prevent build-up of fissile material the sumps are frequently flushed which generates liquid waste and is prone to human error. The development of inserts filled with a neutron poison will allow a reduction in the frequency of flushing. Due to concrete deterioration and deformation of the sump liners the current dimensions of the sumps are unknown. Knowledge of these dimensions is necessary for development of the inserts. To solve this problem a remote Sump Measurement System was designed, fabricated, and tested to aid development of the sump inserts.
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- DE-AC09-96SR18500
- OSTI ID:
- 921681
- Report Number(s):
- WSRC-STI-2007-00653; TRN: US0800795
- Resource Relation:
- Conference: ANS Robotics and Remote Systems Topical Meeting
- Country of Publication:
- United States
- Language:
- English
Similar Records
F and H-Canyon sump criticality analysis 12-rad exposure times
H-Canyon Jumper Gasket Sealing Evaluation
F-Canyon Suspension and Deactivation Safety Analysis Reports
Technical Report
·
Fri May 12 00:00:00 EDT 2000
·
OSTI ID:921681
H-Canyon Jumper Gasket Sealing Evaluation
Technical Report
·
Tue Nov 01 00:00:00 EDT 2022
·
OSTI ID:921681
F-Canyon Suspension and Deactivation Safety Analysis Reports
Conference
·
Fri Apr 30 00:00:00 EDT 2004
·
OSTI ID:921681