Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Disposable Electrochemical Immunosensor Diagnosis Device Based on Nanoparticle Probe and Immunochromatographic Strip

Journal Article · · Analytical Chemistry, 79(20):7644-7653
DOI:https://doi.org/10.1021/ac070691i· OSTI ID:919288

We describe a disposable electrochemical immunosensor diagnosis device that is based on the immunochromatographic strip technique and an electrochemical immunoassay based on quantum dot (QD, CdS@ZnS) labels. The device takes advantage of the speed and low-cost of the conventional immunochromatographic strip test and the high-sensitivity of the nanoparticle-based electrochemical immunoassay. A sandwich immunoreaction was performed on the immunochromatographic strip, and the captured QD labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable-screen-printed electrode, which is embedded underneath the membrane on the test zone. The new device coupled with a portable electrochemical analyzer shows great promise for in-field and point-of-care quantitative testing of disease-related protein biomarkers. The parameters (e.g., voltammetric measurement of QD labels, antibody immobilization, the loading amount of QD-antibody, and the immunoreaction time) that govern the sensitivity and reproducibility of the device were optimized with IgG model analyte. The voltammetric response of the optimized device is highly linear over the range of 0.1 to 10 ng mL-1 IgG, and the limit of detection is estimated to be 30 pg mL-1 in association with a 7-min immunoreaction time. The detection limit was improved to 10 pg mL-1 using a 20-min immunoreaction time. The new disposable electrochemical diagnosis device thus provides a more user-friendly, rapid, clinically accurate, less expensive, and quantitative tool for protein detection.

Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US), Environmental Molecular Sciences Laboratory (EMSL)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
919288
Report Number(s):
PNNL-SA-56511; 24822; 400412000
Journal Information:
Analytical Chemistry, 79(20):7644-7653, Journal Name: Analytical Chemistry, 79(20):7644-7653 Journal Issue: 20 Vol. 79; ISSN ANCHAM; ISSN 0003-2700
Country of Publication:
United States
Language:
English

Similar Records

Multiplex Electrochemical Immunoassay Using Gold Nanoparticle Probes and Immunochromatographic Strips
Journal Article · Mon Oct 20 00:00:00 EDT 2008 · Electrochemistry Communications, 10(10):1636-1640 · OSTI ID:949928

A nanoparticle label/immunochromatographic electrochemical biosensor for rapid and sensitive detection of prostate-specific antigen
Journal Article · Sun Jun 15 00:00:00 EDT 2008 · Biosensors and Bioelectronics, 23(11):1659-1665 · OSTI ID:934397

A Renewable Electrochemical Magnetic Immunosensor Based on Gold Nanoparticle Labels
Journal Article · Tue May 24 00:00:00 EDT 2005 · Journal of Nanoscience and Nanotechnology, 5(7):1060-1065 · OSTI ID:15016521