The Cold Mass Support System and the Helium Cooling System for theMICE Focusing Solenoid

Journal Article · · IEEE Transactions on Applied Superconductivity
OSTI ID:918477
The heart of the absorber focus coil (AFC) module for the muon ionization cooling experiment (MICE) is the two-coil superconducting solenoid that surrounds the muon absorber. The superconducting magnet focuses the muons that are cooled using ionization cooling, in order to improve the efficiency of cooling. The coils of the magnet may either be run in the solenoid mode (both coils operate at the same polarity) or the gradient (the coils operate at opposite polarity). The AFC magnet cold mass support system is designed to carry a longitudinal force up to 700 kN. The AFC module will be cooled using three pulse tube coolers that produce 1.5 W of cooling at 4.2 K. One of the coolers will be used to cool the liquid (hydrogen or helium) absorber used for ionization cooling. The other two coolers will cool the superconducting solenoid. This report will describe the MICE AFC magnet. The cold mass supports will be discussed. The reasons for using a pulsed tube cooler to cool this superconducting magnet will also be discussed.
Research Organization:
Ernest Orlando Lawrence Berkeley NationalLaboratory, Berkeley, CA (US)
Sponsoring Organization:
USDOE. Office of the Chief Financial Officer. Other Costsand Credits
DOE Contract Number:
AC02-05CH11231
OSTI ID:
918477
Report Number(s):
LBNL--61384; BnR: YN0100000
Journal Information:
IEEE Transactions on Applied Superconductivity, Journal Name: IEEE Transactions on Applied Superconductivity Journal Issue: 2 Vol. 17
Country of Publication:
United States
Language:
English

Similar Records

The Helium Cooling System and Cold Mass Support System for theMICE Coupling Solenoid
Journal Article · Mon Aug 27 00:00:00 EDT 2007 · IEEE Transactions on Applied Superconductivity · OSTI ID:932702

The Mice Focusing Solenoids and their Cooling System
Conference · Fri May 07 00:00:00 EDT 2004 · OSTI ID:918557

Progress on the MICE Tracker Solenoid
Conference · Sat Jun 10 00:00:00 EDT 2006 · OSTI ID:918620