Radiological Dose Calculations for Fusion Facilities
This report summarizes the results and rationale for radiological dose calculations for the maximally exposed individual during fusion accident conditions. Early doses per unit activity (Sieverts per TeraBecquerel) are given for 535 magnetic fusion isotopes of interest for several release scenarios. These data can be used for accident assessment calculations to determine if the accident consequences exceed Nuclear Regulatory Commission and Department of Energy evaluation guides. A generalized yearly dose estimate for routine releases, based on 1 Terabecquerel unit releases per radionuclide, has also been performed using averaged site parameters and assumed populations. These routine release data are useful for assessing designs against US Environmental Protection Agency yearly release limits.
- Research Organization:
- Idaho National Laboratory (INL)
- Sponsoring Organization:
- DOE - SC
- DOE Contract Number:
- AC07-99ID13727;
- OSTI ID:
- 910723
- Report Number(s):
- INEEL/EXT-03-00405
- Country of Publication:
- United States
- Language:
- English
Similar Records
Radiological assessments for the National Ignition Facility
Radiological assessments for the National Ignition Facility
Radiological assessment. A textbook on environmental dose analysis
Conference
·
Thu Aug 01 00:00:00 EDT 1996
·
OSTI ID:381735
Radiological assessments for the National Ignition Facility
Journal Article
·
Mon Dec 30 23:00:00 EST 1996
· Fusion Technology
·
OSTI ID:447269
Radiological assessment. A textbook on environmental dose analysis
Technical Report
·
Thu Sep 01 00:00:00 EDT 1983
·
OSTI ID:5407895