Effect of delayed link failure on probability of loss of assured safety in temperature-dependent systems with multiple weak and strong links.

Technical Report ·
DOI:https://doi.org/10.2172/910200· OSTI ID:910200
 [1]; ;  [2]
  1. ProStat, Mesa, AZ
  2. Arizona State University, Tempe, AZ

Weak link (WL)/strong link (SL) systems constitute important parts of the overall operational design of high consequence systems, with the SL system designed to permit operation of the system only under intended conditions and the WL system designed to prevent the unintended operation of the system under accident conditions. Degradation of the system under accident conditions into a state in which the WLs have not deactivated the system and the SLs have failed in the sense that they are in a configuration that could permit operation of the system is referred to as loss of assured safety. The probability of such degradation conditional on a specific set of accident conditions is referred to as probability of loss of assured safety (PLOAS). Previous work has developed computational procedures for the calculation of PLOAS under fire conditions for a system involving multiple WLs and SLs and with the assumption that a link fails instantly when it reaches its failure temperature. Extensions of these procedures are obtained for systems in which there is a temperature-dependent delay between the time at which a link reaches its failure temperature and the time at which that link actually fails.

Research Organization:
Sandia National Laboratories
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
910200
Report Number(s):
SAND2007-1907
Country of Publication:
United States
Language:
English

Similar Records

CPLOAS_2 User Manual
Technical Report · Fri May 01 00:00:00 EDT 2015 · OSTI ID:1183637

Probability of Loss of Assured Safety in Systems with Multiple Time-Dependent Failure Modes
Technical Report · Sat Sep 01 00:00:00 EDT 2012 · OSTI ID:1088055

CPLOAS_2 User Manual
Technical Report · Mon Oct 01 00:00:00 EDT 2012 · OSTI ID:1204067