Contribution to the safety assessment of instrumentation and control software for nuclear power plants: Application to SPIN N4
- and others
1300 MWe pressurised water reactors (PWRs), like the 1400 MWe reactors, operate with microprocessor-based safety systems. This is particularly the case for the Digital Integrated Protection System (SPIN), which trips the reactor in an emergency and sets in action the safeguard functions. The softwares used in these systems must therefore be highly dependable in the execution of their functions. In the case of SPIN, three players are working at different levels to achieve this goal: the protection system manufacturer, Merlin Gerin; the designer of the nuclear steam supply system, Framatome; the operator of the nuclear power plants, Electricite de France (EDF), which is also responsible for the safety of its installations. Regulatory licenses are issued by the French safety authority, the Nuclear Installations Safety Directorate (French abbreviation DSIN), subsequent to a successful examination of the technical provisions adopted by the operator. This examination is carried out by the IPSN and the standing group on nuclear reactors. This communication sets out: the methods used by the manufacturer to develop SPIN software for the 1400 MWe PWRs (N4 series); the approach adopted by the IPSN to evaluate the safety software of the protection system for the N4 series of reactors.
- Research Organization:
- Nuclear Regulatory Commission, Washington, DC (United States). Office of Nuclear Regulatory Research; Brookhaven National Lab., Upton, NY (United States)
- OSTI ID:
- 90925
- Report Number(s):
- NUREG/CP--0140-Vol.1; ON: TI95011672
- Country of Publication:
- United States
- Language:
- English
Similar Records
In-vessel hydrogen production assessment during severe accident sequences
Improvements in VAMCIS: A 1E on-line monitoring system for continuous measurement of steam generator leak rates
Contribution to the safety assessment of instrumentation and control software for nuclear power plants: Application to SPIN N4
Journal Article
·
Mon Dec 30 23:00:00 EST 1996
· Transactions of the American Nuclear Society
·
OSTI ID:437041
Improvements in VAMCIS: A 1E on-line monitoring system for continuous measurement of steam generator leak rates
Conference
·
Tue Oct 31 23:00:00 EST 1989
· Transactions of the American Nuclear Society; (United States)
·
OSTI ID:5374435
Contribution to the safety assessment of instrumentation and control software for nuclear power plants: Application to SPIN N4
Conference
·
Sat Oct 01 00:00:00 EDT 1994
·
OSTI ID:54595