Remote Chemical Detection using Quantum Cascade Lasers
Conference
·
OSTI ID:899817
The Infrared Technologies Program at the Pacific Northwest National Laboratory (PNNL) is focused on the science and technology of remote and in-situ chemical sensors for detecting proliferation and countering terrorism. The program is focusing on the infrared detection of gaseous species including chemical warfare agents and gases associated with the production of chemical and nuclear weapons. Several sensors under development are based on miniature infrared quantum cascade (QC) lasers constructed of semiconductor material. The QC laser is unique in that by simply changing the thickness of the semiconductor layers, the laser's wavelength can be changed to target molecular absorption features of specific chemicals. For remote sensing over long optical paths, QC lasers are applied to remote areas using the differential-absorption LIDAR technique. Using a single laser, this technique can easily monitor large areas that would require a large network of point sensors. The original remote sensing configuration, suitable for laboratory applications, consisted of an optical table, laser, beam expander, telescope, mirror, and various supporting electronic and optical components. Recently, PNNL began development of a ruggedized version to conduct experiments in real-world conditions. To reduce the effects of thermal distortion, the system had to be operated from within a large, well insulated, temperature-controlled trailer. The optical breadboard was attached to 4 shock-mounts to reduce shock and vibrational loads to the optical set-up during transport. A custom jacking system using electromechanical actuators was designed to affix the optical table directly to the ground through penetrations in the trailer floor. The jacking system allows remote sensing at longer ranges (up to 5 km) by eliminating jitter caused by wind or personnel movement within the trailer. A computer-controlled gimbal-mounted mirror was added to allow the laser beam to be accurately pointed in both the vertical and horizontal plane. Mechanical tests and finite element analysis were undertaken to verify that the gimbal drives and mounting hardware had sufficient capacity to handle the inertia of the large 22-inch diameter mirror while maintaining adequate mirror flatness. This paper will provide an overview of the remote chemical detection system and will describe innovative optical mechanical solutions developed to overcome several alignment and stability issues.
- Research Organization:
- Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-76RL01830
- OSTI ID:
- 899817
- Report Number(s):
- PNNL-SA-47429; NN2001000
- Country of Publication:
- United States
- Language:
- English
Similar Records
Fieldable Fourier Transform Spectrometer: System Construction, Background Variability Measurements, and Chemical Attack Warning Experiments
Ultra-Trace Chemical Sensing with Long-Wave Infrared Cavity-Enhanced Spectroscopic Sensors
FY 2005 Quantum Cascade Laser Alignment System Final Report
Technical Report
·
Tue Oct 01 00:00:00 EDT 2002
·
OSTI ID:900223
Ultra-Trace Chemical Sensing with Long-Wave Infrared Cavity-Enhanced Spectroscopic Sensors
Technical Report
·
Wed Feb 19 23:00:00 EST 2003
·
OSTI ID:969187
FY 2005 Quantum Cascade Laser Alignment System Final Report
Technical Report
·
Tue Jan 10 23:00:00 EST 2006
·
OSTI ID:889069