Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

High temperature electrochemical corrosion rate probes for combustion environments

Conference ·
OSTI ID:898982

Electrochemical corrosion rate probes have been constructed and tested along with mass loss coupons in an air plus water vapor and a N2/O2/CO2 plus water vapor environment. Temperatures ranged from 200? to 700?C. Results show that electrochemical corrosion rates for ash-covered mild steel are a function of time, temperature and process environment. Correlation between the electrochemical and mass loss corrosion rates was poor.

Research Organization:
Albany Research Center (ARC), Albany, OR
Sponsoring Organization:
USDOE - Office of Fossil Energy (FE)
OSTI ID:
898982
Report Number(s):
DOE/ARC-2004-034
Country of Publication:
United States
Language:
English