Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Carbon Dioxide Capture from Flue Gas Using Dry, Regenerable Sorbents

Technical Report ·
DOI:https://doi.org/10.2172/895860· OSTI ID:895860
This report describes research conducted between July 1, 2006 and September 30, 2006 on the use of dry regenerable sorbents for removal of carbon dioxide (CO{sub 2}) from coal combustion flue gas. Modifications to the integrated absorber/ sorbent regenerator/ sorbent cooler system were made to improve sorbent flow consistency and measurement reliability. Operation of the screw conveyor regenerator to achieve a sorbent temperature of at least 120 C at the regenerator outlet is necessary for satisfactory carbon dioxide capture efficiencies in succeeding absorption cycles. Carbon dioxide capture economics in new power plants can be improved by incorporating increased capacity boilers, efficient flue gas desulfurization systems and provisions for withdrawal of sorbent regeneration steam in the design.
Research Organization:
Research Triangle Institute
Sponsoring Organization:
USDOE
DOE Contract Number:
FC26-00NT40923
OSTI ID:
895860
Country of Publication:
United States
Language:
English