Title: Thermal Response of the 21-PWR Waste Package to a Fire Accident

Technical Report ·
DOI:https://doi.org/10.2172/894192· OSTI ID:894192

The objective of this calculation is to evaluate the thermal response of the 21-PWR WP (pressurized water reactor waste package) to the regulatory fire event. The scope of this calculation is limited to the two-dimensional waste package temperature calculations to support the waste package design. The information provided by the sketches attached to this calculation (Attachment IV) is that of the potential design of the type of waste package considered in this calculation. The procedure AP-3.12Q.Calculations (Reference 1), and the Development Plan (Reference 24) are used to develop this calculation.

Research Organization:
Yucca Mountain Project, Las Vegas, NV (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
NA
OSTI ID:
894192
Report Number(s):
CAL-UDC-TH-000002, Rev. 00; MOL.20001016.0007, DC# 26134; TRN: US0700068
Country of Publication:
United States
Language:
English

Similar Records

Horizontal Drop of 21- PWR Waste Package
Technical Report · Thu Apr 26 00:00:00 EDT 2001 · OSTI ID:894192

Swing-Down of 21-PWR Waste Package
Technical Report · Fri May 04 00:00:00 EDT 2001 · OSTI ID:894192

Horizontal Drop of 21- PWR Waste Package