Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

The Effects of Unheated Sections on Mositure Transport in the Emplacement Drift

Technical Report ·
DOI:https://doi.org/10.2172/893844· OSTI ID:893844

A thermal-hydrologic natural-ventilation model is configured for simulating temperature, humidity, and condensate distributions in the coupled domains of the in-drift airspace and the near-field rockmass. Meaningful results are obtained from the model for a practical application in which the beneficial effects of unheated drift sections are analyzed. Sensitivity to the axial dispersion coefficient is also studied with the model.

Research Organization:
Yucca Mountain Project, Las Vegas, Nevada
Sponsoring Organization:
USDOE
OSTI ID:
893844
Report Number(s):
NA; MOL.20060713.0523, DC# 47276
Country of Publication:
United States
Language:
English