Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Radon removal from flowing air by a water scrubber

Journal Article · · Transactions of the American Nuclear Society
OSTI ID:89378
As part of a process that is being developed to vitrify tailings from Belgian Congo ore that is stored in large silos at a former U.S. Department of Energy uranium-processing facility in southwestern Ohio, process off-gas is produced that contains large concentrations of radon gas (on the order of hundreds of thousands of picocuries per litre). To meet U.S. Environmental Protection Agency restrictions, the process off-gas must be stripped of its radon content before it is vented to the atmosphere. It is appropriate to consider a charcoal bed as part of an off-gas treatment system for the removal of radon at the vitrification facility. However, a difficulty arises in incorporating a charcoal bed into an off-gas treatment system at a vitrification facility. That difficulty is that the capability of the charcoal bed to capture and retain radon gas decreases with increasing bed temperature. Thus, it may be necessary to include a water scrubber in the off-gas treatment system to cool the process off-gas before it is passed through the charcoal bed.
OSTI ID:
89378
Report Number(s):
CONF-941102--
Journal Information:
Transactions of the American Nuclear Society, Journal Name: Transactions of the American Nuclear Society Vol. 71; ISSN 0003-018X; ISSN TANSAO
Country of Publication:
United States
Language:
English

Similar Records

Characteristics of Fernald's K-65 residue before, during and after vitrification
Technical Report · Thu Jan 31 23:00:00 EST 1991 · OSTI ID:5429240

Time-dependent response of a charcoal bed to radon and water vapor in flowing air
Journal Article · Sat Dec 30 23:00:00 EST 1995 · Transactions of the American Nuclear Society · OSTI ID:186502

Results of vitrifying Fernald OU-4 wastes
Conference · Sun Jan 31 23:00:00 EST 1993 · OSTI ID:10143466