Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Heber Geothermal Project, binary-cycle demonstration plant. Volume II. Proposal abstract

Technical Report ·
DOI:https://doi.org/10.2172/892751· OSTI ID:892751
San Diego Gas and Electric (SDG and E) believes that the binary-cycle offers an improved method of converting moderate temperature geothermal resources into electric power. The process, shown schematically in figure 1-1, has significant advantages over existing methods of geothermal power generation. The advantages of the binary process are that greater amounts of power can be generated from a given resource, fewer wells are needed to support a given power output, and the binary-cycle is expected to be more economical than the flash process for this type of resource. Another advantage is that the binary-cycle is a closed process and thus enhances environmental acceptability. In addition, this process is applicable to a larger range of the nations geothermal reservoirs. It is estimated that 80% of the nation's hydrothermal resources can be classified as moderate temperature (300 to 410 F) resources. The flash process, commonly used to convert high temperature geothermal resources to electric power, is technically feasible for moderate temperature resources. However, when compared to the binary process for moderate temperature applications, the flash process conversion efficiency is lower, environmental impacts may require abatement, and power production costs may not be commercially competitive.
Research Organization:
San Diego Gas & Electric, San Diego, CA
Sponsoring Organization:
USDOE
OSTI ID:
892751
Report Number(s):
HEBER-79-002
Country of Publication:
United States
Language:
English

Similar Records

Session 9: Heber Geothermal Binary Demonstration Project
Conference · Wed Nov 30 23:00:00 EST 1983 · OSTI ID:838149

Heber binary project
Conference · Wed Aug 01 00:00:00 EDT 1984 · Proc., Intersoc. Energy Convers. Eng. Conf.; (United States) · OSTI ID:5819474

Heber binary-cycle geothermal demonstration power plant: summary of technical characteristics
Technical Report · Sun Jun 01 00:00:00 EDT 1986 · OSTI ID:5709383