Optimum depressurization for a short-term station blackout in a BWR-6 with high-burnup fuel

Journal Article · · Transactions of the American Nuclear Society
OSTI ID:89180
 [1]
  1. Oak Ridge National Lab., TN (United States)

This study investigates the optimum depressurization time for a boiling water reactor (BWR)-6 reactor during a short-term station blackout severe accident. The study was performed with the MELCOR severe accident code, version 1.8.2 NM. The plant analyzed is the Grand Gulf Nuclear Station, a BWR-6 with a power of 3833 MW(thermal) and a Mark-III containment. These calculations assume that the fuel in the core is at the end of life (high burnup).

OSTI ID:
89180
Report Number(s):
CONF-941102--
Journal Information:
Transactions of the American Nuclear Society, Journal Name: Transactions of the American Nuclear Society Vol. 71; ISSN 0003-018X; ISSN TANSAO
Country of Publication:
United States
Language:
English

Similar Records

Effect of the timing of vessel depressurization on a short-term station blackout in a BWR-4 performed with the MELCOR code
Conference · Tue Dec 31 23:00:00 EST 1991 · Transactions of the American Nuclear Society; (United States) · OSTI ID:6682722

Containment failure time and mode for a low-pressure short-term station blackout in a BWR-4 with Mark-I containment
Conference · Thu Dec 31 23:00:00 EST 1992 · Transactions of the American Nuclear Society; (United States) · OSTI ID:7129195

MELCOR-calculated in-containment source terms using different release models
Journal Article · Mon Dec 30 23:00:00 EST 1996 · Transactions of the American Nuclear Society · OSTI ID:436957