COMPARISON OF DOUBLE BEND AND TRIPLE BEND ACHROMATIC LATTICE STRUCTURES AND NSLS-II.
Conference
·
OSTI ID:891552
The Double Bend Achromatic (DBA) and the Triple Bend Achromatic (TBA) lattice have been studied rather extensively for use for the NSLS-II storage ring. The advantage of the TBA compared to the DBA in terms of emittance per period is well known. However, the DBA has the advantage of greater number of ID straight sections for the users and maybe easier to tune the dispersive section for reduced chromatic sextupole strength. We present a comparison of these lattices based on optimization of the non-linear driving terms using high order achromatic cancellation of driving terms of the nonlinear lattice.
- Research Organization:
- BROOKHAVEN NATIONAL LABORATORY
- Sponsoring Organization:
- DOE/SC
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 891552
- Report Number(s):
- BNL--76923-2006-CP; KC0204011
- Country of Publication:
- United States
- Language:
- English
Similar Records
OPTIMIZING THE DYNAMIC APERTURE FOR TRIPLE BEND ACHROMATIC LATTICES.
A comparison of the Chasman-Green and triple bend achromat lattices
Flexibility in the Design of the NSLS-II Lattice
Conference
·
Mon Jun 26 00:00:00 EDT 2006
·
OSTI ID:891553
A comparison of the Chasman-Green and triple bend achromat lattices
Journal Article
·
Fri Feb 28 23:00:00 EST 1986
· Particle Accelerators
·
OSTI ID:1000344
Flexibility in the Design of the NSLS-II Lattice
Conference
·
Mon May 04 00:00:00 EDT 2009
·
OSTI ID:958690