Simulation of HOM Leakage in the PEP-II Bellows

Conference ·
OSTI ID:890452
An important factor that limits the PEP-II from operating at high currents is higher-order-mode (HOM) heating of the bellows. One source of HOM heating is the formation of trapped modes at the bellows as a result of geometry variation in the vacuum chamber, for example, the masking near the central vertex chamber. Another source comes from HOMs generated upstream that leak through the gaps between the bellows fingers. Modeling the fine details of the bellows and the surrounding geometry requires the resolution and accuracy only possible with a large number of mesh points on an unstructured grid. We use the parallel finite element eigensolver Omega3P for trapped mode calculations and the S-matrix solver S3P for transmission analysis. The damping of the HOMs by the use of absorbers inside the bellows will be investigated.
Research Organization:
Stanford Linear Accelerator Center (SLAC)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76SF00515
OSTI ID:
890452
Report Number(s):
SLAC-PUB-11259
Country of Publication:
United States
Language:
English

Similar Records

RF MODES IN THE PEP-II SHIELDED VERTEX BELLOWS
Technical Report · Tue Jun 10 00:00:00 EDT 2003 · OSTI ID:813229

Damping Higher Order Modes in the PEP-II B-Factory Vertex Bellows
Conference · Thu Jun 30 00:00:00 EDT 2005 · OSTI ID:881138

HOM/LOM Coupler Study for the ILC Crab Cavity
Technical Report · Mon Apr 16 00:00:00 EDT 2007 · OSTI ID:902484