The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.
Research Organization:
Stanford Linear Accelerator Center (SLAC)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76SF00515;
OSTI ID:
890401
Report Number(s):
SLAC-PUB-11275
Conference Information:
Presented atParticle Accelerator Conference (PAC 05), , 5/16/2005-5/20/2005
Country of Publication:
United States
Language:
English

Similar Records

Measurements of Coherent Synchrotron Radiation and its Impact on the LCLS Electron Beam
Conference · Tue Sep 23 20:00:00 EDT 2008 · OSTI ID:938637

Linac Coherent Light Source Longitudinal Feedback Model
Conference · Tue Jun 14 20:00:00 EDT 2005 · OSTI ID:890400

Measurements and Modeling of Coherent Synchrotron Radiation and its Impact on the LCLS Electron Beam
Journal Article · Wed Dec 17 19:00:00 EST 2008 · Submitted to Phys. Rev. ST Accel. Beams · OSTI ID:944552