Report on Analyses of WAC Samples of Evaporator Overheads - 2004

Technical Report ·
DOI:https://doi.org/10.2172/890158· OSTI ID:890158
In November and December of 2004, the Tank Farm submitted annual samples from 2F, 2H and 3H Evaporator Overhead streams for characterization to verify compliance with the new Effluent Treatment Facility (ETF) Waste Acceptance Criteria (WAC) and to look for organic species. With the exception of slightly high ammonia in the 2F evaporator overheads and high radiation control guide number for the 3H and 2F evaporator overhead samples, all the overheads samples were found to be in compliance with the Effluent Treatment Facility WAC. The ammonium concentration in the 2F-evaporator overhead, at 33 mg/L, was above the ETF waste water collection tank (WWCT) limits of 28 mg/L. The RCG Number for the 3H and 2F evaporator samples at, respectively, 1.38E-02 and 8.24E-03 were higher than the WWCT limit of 7.69E-03. The analytical detection limits for americium-241 and radium-226 in the evaporator samples were not consistently met because of low WWCT detection limits and insufficient evaporator samples.
Research Organization:
SRS
Sponsoring Organization:
DOE
DOE Contract Number:
AC09-96SR18500
OSTI ID:
890158
Report Number(s):
WSRC-TR-2005-00081
Country of Publication:
United States
Language:
English