Title: A second beam-diagnostic beamline for the advanced lightsource

Abstract

A second beamline, BL 7.2, completely dedicated to beam diagnostics is being installed at the Advanced Light Source (ALS). The design has been optimized for the measurement of the momentum spread and emittance of the stored beam in combination with the existing diagnostic beamline, BL 3.1. A detailed analysis of the experimental error has allowed the definition of the system parameters. The obtained requirements found a good matching with a simple and reliable system based on the detection of X-ray synchrotron radiation (SR) through a pinhole system. The actual beamline, which also includes a port for visible and infrared SR as well as an X-ray beam position monitor (BPM), is mainly based on the design of two similar diagnostic beamlines at BESSY II. This approach allowed a significant saving in time, cost and engineering effort. The design criteria, including a summary of the experimental error analysis, as well as a brief description of the beamline are presented.

Authors:
; ; ; ;
Publication Date:
Research Org.:
Ernest Orlando Lawrence Berkeley NationalLaboratory, Berkeley, CA (US)
Sponsoring Org.:
USDOE Director. Office of Science. Office of Basic EnergySciences
OSTI Identifier:
886757
Report Number(s):
LBNL-52663
R&D Project: A580AP; BnR: KC0204016; TRN: US0604015
DOE Contract Number:  
DE-AC02-05CH11231
Resource Type:
Conference
Resource Relation:
Conference: 2003 Particle Accelerator Conference, Portland,OR, May 12-16, 2003
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; ACCELERATORS; ADVANCED LIGHT SOURCE; BEAM POSITION; DESIGN; DETECTION; MONITORS; SYNCHROTRON RADIATION; synchrotron light monitor beam diagnostics ALS

Citation Formats

Sannibale, Fernando, Baum, Dennis, Kelez, Nicholas, Scarvie, Tom, and Holldack, Karsten. A second beam-diagnostic beamline for the advanced lightsource. United States: N. p., 2003. Web.
Sannibale, Fernando, Baum, Dennis, Kelez, Nicholas, Scarvie, Tom, & Holldack, Karsten. A second beam-diagnostic beamline for the advanced lightsource. United States.
Sannibale, Fernando, Baum, Dennis, Kelez, Nicholas, Scarvie, Tom, and Holldack, Karsten. Thu . "A second beam-diagnostic beamline for the advanced lightsource". United States. https://www.osti.gov/servlets/purl/886757.
@article{osti_886757,
title = {A second beam-diagnostic beamline for the advanced lightsource},
author = {Sannibale, Fernando and Baum, Dennis and Kelez, Nicholas and Scarvie, Tom and Holldack, Karsten},
abstractNote = {A second beamline, BL 7.2, completely dedicated to beam diagnostics is being installed at the Advanced Light Source (ALS). The design has been optimized for the measurement of the momentum spread and emittance of the stored beam in combination with the existing diagnostic beamline, BL 3.1. A detailed analysis of the experimental error has allowed the definition of the system parameters. The obtained requirements found a good matching with a simple and reliable system based on the detection of X-ray synchrotron radiation (SR) through a pinhole system. The actual beamline, which also includes a port for visible and infrared SR as well as an X-ray beam position monitor (BPM), is mainly based on the design of two similar diagnostic beamlines at BESSY II. This approach allowed a significant saving in time, cost and engineering effort. The design criteria, including a summary of the experimental error analysis, as well as a brief description of the beamline are presented.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2003},
month = {5}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: