Laser-Induced Damage in DKDP Crystals under Simultaneous Exposure to Laser Harmonics
While KDP and DKDP crystals remain the only viable solution for frequency conversion in large aperture laser systems in the foreseeable future, our understanding of damage behavior in the presence of multiple colors is very limited. Such conditions exist during normal operation where, for third harmonic generation, 1{omega}, 2{omega} and 3{omega} components are present with different energy ratios as they propagate inside the crystal. The objective of this work is to shed light into the damage behavior of frequency conversion crystals during operational conditions as well as probe the fundamental mechanisms of damage initiation. We have performed a series of experiments to quantify the damage performance of pristine (unconditioned) DKDP material under simultaneous exposure to 2{omega} and 3{omega} laser pulses from a 3-ns Nd:YAG laser system as a function of the laser influences at each frequency. Results show that simultaneous dual wavelength exposure leads to a much larger damage density as compared to the total damage resulting from separate exposure at each wavelength. Furthermore, under such excitation conditions, the damage performance is directly related to and can be predicted from the damage behavior of the crystal at each wavelength separately while the mechanism and type of defects responsible for damage initiation are shown to be the same at both 2{omega} and 3{omega} excitation.
- Research Organization:
- Lawrence Livermore National Laboratory (LLNL), Livermore, CA
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 883573
- Report Number(s):
- UCRL-PROC-216804
- Country of Publication:
- United States
- Language:
- English
Similar Records
A multi-dimensional investigation of laser conditioning in KDP and DKDP crystals
Simple model of laser damage initiation and conditioning in frequency conversion crystals