Performance Evaluation of a 1.5-kWdc a-Si PV Array Using the PVUSA Power Rating Method at NREL's Outdoor Test Facility
Conference
·
OSTI ID:882813
As part of the work conducted in the PV Systems Reliability and Performance R&D Task, a 1.5-kWdc photovoltaic (PV) array consisting of 36 Solarex MST-43MV dual-junction a-Si modules was installed and its performance monitored for almost six years (September 1999 through May 2005) at the National Renewable Energy Laboratory (NREL) Outdoor Test Facility (OTF). This paper describes the system and its performance based on the PV for Utility-Scale Applications (PVUSA) power rating method.