DEVELOPMENT OF A COMPACT RADIOGRAPHY ACCELERATOR USING DIELECTRIC WALL ACCELERATOR TECHNOLOGY
We are developing an inexpensive compact accelerator system primarily intended for pulsed radiography. Design characteristics are an 8 MeV endpoint energy, 2 kA beam current, a cell gradient of approximately 3 MV/m (for an overall accelerator length is 2-3 m), and <$1/Volt capital costs. Such designs have been made possible with the development of high specific energy dielectrics (>10J/cm{sup 3}), specialized transmission line designs and multi-gap laser triggered low jitter (<1 ns) gas switches. In this geometry, the pulse forming lines, switches, and insulator/beam pipe are fully integrated within each cell to form a compact, stand-alone, stackable unit. We detail our research and modeling to date, recent high voltage test results, and the integration concept of the cells into a radiographic system.
- Research Organization:
- Lawrence Livermore National Laboratory (LLNL), Livermore, CA
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 877937
- Report Number(s):
- UCRL-CONF-212251-REV-1
- Country of Publication:
- United States
- Language:
- English
Similar Records
BEAM TRANSPORT IN A COMPACT DIELECTRIC WALL INDUCTION ACCELERATOR SYSTEM FOR PULSED RADIOGRAPHY
TRANSVERSE BEAM INSTABILITY IN A COMPACT DIELECTRIC WALL INDUCTION ACCELERATOR