The PEP-II Movable Collimators

Conference ·
OSTI ID:877438
Three movable collimators have been manufactured for installation in the PEP-II LER and HER beamlines upstream of BaBar to improve backgrounds in BaBar by a factor of 2. Each collimator has a pair of horizontally opposed, water cooled jaws with RF finger seals all around the edge of the jaws, these seals are the only sliding parts inside the vacuum chamber. Each jaw travels independently through a distance of 16.5 mm (LER) or 21mm (HER) and is supported above the collimator from motorized slideways with position feedback. The larger HER collimator has a titanium sublimation pump incorporated into the underside of the collimator, pumping through RF screens in the bottom of the chamber. Water cooled fixed ramps protect the leading and trailing edges of the jaws.
Research Organization:
Stanford Linear Accelerator Center (SLAC)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76SF00515
OSTI ID:
877438
Report Number(s):
SLAC-PUB-11752
Country of Publication:
United States
Language:
English

Similar Records

PEP-II New High Power Low Impedance Movable Collimator
Technical Report · Wed Sep 20 00:00:00 EDT 2000 · OSTI ID:765016

The PEP-II Lower Pressure HER Vacuum Chamber
Conference · Sun Mar 12 23:00:00 EST 2006 · OSTI ID:877437

The PEP-II Project: Low-Energy Ring Design and Project Status
Technical Report · Sun Jan 01 23:00:00 EST 2006 · OSTI ID:943453