Moisture conditions in a north-facing wall with cellulose loose-fill insulation: Construction with and without a vapor retarder and air leakage
Conference
·
OSTI ID:87431
- Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Building Physics
- Lund Univ. (Sweden). Dept. of Building Physics
This paper presents the calculated moisture conditions of a wall exposed to a climate equivalent to that in northern Sweden. A north-facing timber wall with a brick facade and cellulose loose-fill thermal insulation is studied both with and without a vapor retarder and air leakage. If the vapor retarder is eliminated from the construction, the moisture levels will increase to unacceptably high values. The construction becomes sensitive to the choice of facing materials and the indoor moisture supply. Air leakage carrying moist air into the construction leads to unacceptably high values even for moderate indoor moisture supplies.
- OSTI ID:
- 87431
- Report Number(s):
- CONF-950104-; TRN: IM9535%%62
- Resource Relation:
- Conference: American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) winter meeting and exhibition, Chicago, IL (United States), 28 Jan - 1 Feb 1995; Other Information: PBD: 1995; Related Information: Is Part Of ASHRAE transactions 1995. Volume 101, Part 1; PB: 1517 p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Efficient application of boron fire retardant to cellulosic loose-fill insulation
Airflows and moisture conditions in walls of manufactured homes
Sealed and Insulated Attic Hygrothermal Performance in New California Homes Using Vapor and Air Permeable Insulation—Field Study and Simulation
Conference
·
Sat Jan 01 00:00:00 EST 1983
· Am. Soc. Test. Mater., Spec. Tech. Publ.; (United States)
·
OSTI ID:87431
Airflows and moisture conditions in walls of manufactured homes
Journal Article
·
Fri Sep 01 00:00:00 EDT 1995
· American Society for Testing and Materials, Special Technical Publication
·
OSTI ID:87431
Sealed and Insulated Attic Hygrothermal Performance in New California Homes Using Vapor and Air Permeable Insulation—Field Study and Simulation
Technical Report
·
Mon Apr 01 00:00:00 EDT 2019
·
OSTI ID:87431
+2 more