Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

EMPLACEMENT SCALE THERMAL EVALUATIONS OF LARGE AND SMALL WP DESIGNS (SCPB: N/A)

Technical Report ·
DOI:https://doi.org/10.2172/862043· OSTI ID:862043
The purpose of this analysis is to calculate the thermal response of the repository host rock and near-field surface temperatures due to the heat produced by drift-emplaced waste packages (WPs). The main objective of the evaluation is to predict time-dependent WP surface temperatures for later use as boundary conditions for detailed thermal evaluations of large and small Multi-Purpose Canisters (MPCs), defense high-level waste (DHLW), and uncanistered spent fuel (UCF) waste package conceptual designs. This analysis will also provide a parametric evaluation of the thermal effects of thermal loading and various emplacement parameters to determine what parameters are important to repository thermal behavior.
Research Organization:
Office of Scientific and Technical Information, Oak Ridge, TN
Sponsoring Organization:
USDOE
OSTI ID:
862043
Report Number(s):
BB0000000-01717-0200-00009 REV 00; MOL.19960624.0097 DC#27387
Country of Publication:
United States
Language:
English