Testing a Passive Autocatalytic Recombiner in the Surtsey Facility
- Sandia National Laboratories
Performance tests of a scaled passive autocatalytic recombine (PAR) were performed in the Surtsey test vessel at Sandia National Laboratories. Measured hydrogen depletion rate data were obtained and compared with previous work. Depletion rate is most likely proportional to PAR scale. PAR performance in steamy environments (with and without hydrophobic coating) was investigated. The tests determined that the PAR startup delay times decrease with increasing hydrogen concentrations in steamy environments. Tests with placement of the PAR near a wall (as opposed to a center location) yielded reduced depletion rates. Tests at low oxygen concentrations also showed a reduced recombination rate. The PAR repeatedly ignited hydrogen at about 6 mol% concentration with a catalyst temperature near 940 K. Velocity data at the PAR exhaust were used to calculate the volumetric flow rate through the PAR as a function of the vessel hydrogen concentration.
- Research Organization:
- Sandia National Labs., Albuquerque, NM (US); Sandia National Labs., Livermore, CA (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 8480
- Report Number(s):
- SAND99-1679J
- Journal Information:
- Nuclear Technology, Journal Name: Nuclear Technology
- Country of Publication:
- United States
- Language:
- English
Similar Records
Testing of a passive autocatalytic recombiner in the Surtsey facility
Analysis of Hydrogen Depletion Using a Scaled Passive Autocatalytic Recombiner