BART stray current prevention
Conference
·
OSTI ID:83087
- BART, Oakland, CA (United States)
BART is a dc-powered transit system that uses its running rails for traction-current negative return. The use of the running rails as part of the electrical-traction circuit presents the engineer with two conflicting electrical requirements. First, the negative return must, at times, be connected to earth and structure to control electrical-fault currents and to limit voltages. Second, the negative return must be electrically insulated (isolated) from earth and structures to minimize stray current and the resultant corrosion. To satisfy both of these requirements, BART developed insulated rail fasteners and diode grounding. This paper describes these system features as well as recent efforts to improve the rail-fastener insulation and negative-return grounding.