A Rich Detector with Two Stage Gas Amplification at Atmospheric Pressure

Journal Article · · Nuclear Instruments and Methods A
OSTI ID:828526
A prototype of a Ring Imaging Cherenkov detector (RICH) with two-stage gas amplification has been developed. The detector consists of a time projection chamber (TPC) with a sensitive volume of 19 x 20 x 6 cm3 followed by a parallel plate avalanche counter (sensitive volume 20 x 5 x 0.4 cm3) and a multiwire proportional chamber (MWPC) with 96 wires 2 mm apart. The gas used was an argon/methane/isobutane mixture (ratio 60/20/20) at atmospheric pressure. TMAE at 15 C served as the photosensitive component. The measurements were done with a calibrated VUV photon source. The following results were obtained: spatial resolution of the MWPC 1.2 mm, spatial resolution of the TPC 800 mm, attachment length (13.0 {+-} 1.6) cm and photon detection efficiency 4.2% corresponding to N0 = 25 cm-1
Research Organization:
Thomas Jefferson National Accelerator Facility, Newport News, VA (US)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC05-84ER40150
OSTI ID:
828526
Report Number(s):
CEBAF-PR-94-21; DOE/ER/40150-2860
Journal Information:
Nuclear Instruments and Methods A, Journal Name: Nuclear Instruments and Methods A Journal Issue: 1 Vol. 343
Country of Publication:
United States
Language:
English

Similar Records

Beam tests of a MWPC with CsI photocathode for Cherenkov Ring Imaging
Journal Article · Tue Aug 01 00:00:00 EDT 1995 · IEEE Transactions on Nuclear Science · OSTI ID:129190

The ring imaging Cherenkov detector for Fermilab experiment 665
Conference · Sun Jan 31 23:00:00 EST 1988 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:7145693

Photon detectors for the HERA-B rich
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:513063