BaBar Forward Endcap Upgrade

Technical Report ·
DOI:https://doi.org/10.2172/826996· OSTI ID:826996

The muon and neutral hadron detector (Instrumented Flux Return or IFR) in the forward endcap of the BaBar detector at SLAC was upgraded by the installation of a new generation of Resistive Plate Chambers (RPCs) and by increasing the absorber. The chamber replacement was made necessary by the rapid aging and efficiency loss of the original BaBar RPCs. Based on our experience with those original RPCs and 24 RPCs with thinner linseed oil treatments, improvements in the design, construction, and testing of the new generation RPCs were implemented and are described in detail.

Research Organization:
Stanford Linear Accelerator Center, Menlo Park, CA (US)
Sponsoring Organization:
USDOE Office of Science (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
826996
Report Number(s):
SLAC-PUB-10477