Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Luminosity for NLC Design Variations(LCC-0014)

Technical Report ·
DOI:https://doi.org/10.2172/826897· OSTI ID:826897
In this note we give Guineapig [l] simulation results for the luminosity and luminosity spectrum of three baseline NLC designs at 0.5 TeV (NLC-A-500, NLCB-500, and NLC-C-500) and 1.0 TeV (NLC-A-1000, NLC-B-1000, and NLC-C-1000) [2]. We examine the effects of variations of several design parameters away from the NLC-B-500 and NLC-B-1000 designs. One of our purposes is to study possible trade-offs of parameters to ease tolerances or increase luminosity. Another (future) application will be to examine how the basic designs might be modified in special cases where one wants to optimize the luminosity for particular physics channels.
Research Organization:
Stanford Linear Accelerator Center, Menlo Park, CA (US)
Sponsoring Organization:
USDOE Office of Science (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
826897
Report Number(s):
SLAC-TN-04-028
Country of Publication:
United States
Language:
English

Similar Records

Effects of Position and Angle Offsets on NLC Luminosity(LCC-0017)
Technical Report · Tue Apr 20 00:00:00 EDT 2004 · OSTI ID:826895

Beam Losses in the NLC Extraction Line for High Luminosity Beam Parameters (LCC-0049)
Technical Report · Thu Mar 18 23:00:00 EST 2004 · OSTI ID:826828

High Luminosity Options for the JLC.NLC at 500 GeV cms(LCC-0004)
Technical Report · Thu Apr 22 00:00:00 EDT 2004 · OSTI ID:826904