In this note we give Guineapig [l] simulation results for the luminosity and luminosity spectrum of three baseline NLC designs at 0.5 TeV (NLC-A-500, NLCB-500, and NLC-C-500) and 1.0 TeV (NLC-A-1000, NLC-B-1000, and NLC-C-1000) [2]. We examine the effects of variations of several design parameters away from the NLC-B-500 and NLC-B-1000 designs. One of our purposes is to study possible trade-offs of parameters to ease tolerances or increase luminosity. Another (future) application will be to examine how the basic designs might be modified in special cases where one wants to optimize the luminosity for particular physics channels.