Bunch length measurements at the Advanced Photon Source (APS) linear accelerator
Conference
·
OSTI ID:82472
Measurements of the APS linac micro-bunch length are performed by backphasing a single 2856-MHz, S-band linac waveguide and using a downstream spectrometer to observe the beam. By measuring the beam width in the dispersive plane as a function of rf power into the linac waveguide, the bunch length can be determined absolutely provided the beam energy and dispersion at the spectrometer are known. The bunch length determined in this fashion is used to calibrate a fifth-harmonic bunch length cavity which is used for real-time bunch length monitoring.
- Research Organization:
- Argonne National Lab., IL (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 82472
- Report Number(s):
- ANL/ASD/CP--85009; CONF-950512--235; ON: DE95013756
- Country of Publication:
- United States
- Language:
- English
Similar Records
Status of the Advanced Photon Source (APS) linear accelerator
Status of the Advanced Photon Source (APS) linear accelerator
Performance of the Advanced Photon Source (APS) linear accelerator
Conference
·
Thu Sep 01 00:00:00 EDT 1994
·
OSTI ID:10181978
Status of the Advanced Photon Source (APS) linear accelerator
Conference
·
Sun Aug 01 00:00:00 EDT 1993
·
OSTI ID:10176978
Performance of the Advanced Photon Source (APS) linear accelerator
Conference
·
Thu Jun 01 00:00:00 EDT 1995
·
OSTI ID:95352