Radiation shielding calculations for MuCool test area at Fermilab
The MuCool Test Area (MTA) is an intense primary beam facility derived directly from the Fermilab Linac to test heat deposition and other technical concerns associated with the liquid hydrogen targets being developed for cooling intense muon beams. In this shielding study the results of Monte Carlo radiation shielding calculations performed using the MARS14 code for the MuCool Test Area and including the downstream portion of the target hall and berm around it, access pit, service building, and parking lot are presented and discussed within the context of the proposed MTA experimental configuration.
- Research Organization:
- Fermi National Accelerator Laboratory, Batavia, IL (US)
- Sponsoring Organization:
- USDOE Office of Energy Research (ER) (US)
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 824355
- Report Number(s):
- FERMILAB-TM-2248; TRN: US0402021
- Resource Relation:
- Other Information: PBD: 26 May 2004
- Country of Publication:
- United States
- Language:
- English