Effect of Pressure with Wall Heating in Annular Two-Phase Flow

Technical Report ·
DOI:https://doi.org/10.2172/821307· OSTI ID:821307

The local distributions of void fraction, interfacial frequency and velocity have been measured in annular flow of R-134a through a wall-heated, high aspect ratio duct. High aspect ratio ducts provide superior optical access to tubes or irregular geometries. This work expands upon earlier experiments conducted with adiabatic flows in the same test section. Use of thin, transparent heater films on quartz windows provided sufficient electrical power capacity to produce the full range of two-phase conditions of interest. With wall vapor generation, the system pressure was varied from 0.9 to 2.4 MPa, thus allowing the investigation of flows with liquid-to-vapor density ratios covering the range of about 7 to 27, far less than studied in air-water and similar systems. There is evidence that for a given cross-sectional average void fraction, the local phase distributions can be different depending on whether the vapor phase is generated at the wall, or upstream of the test section inlet. In wall-heated flows, local void fraction profiles measured across both the wide and narrow test section dimensions illustrate the profound effect that pressure has on the local flow structure; notably, increasing pressure appears to thin the wall-bounded liquid films and redistribute liquid toward the edges of the test section. This general trend is also manifested in the distributions of mean droplet diameter and interfacial area density, which are inferred from local measurements of void fraction, droplet frequency and velocity. At high pressure, the interfacial area density is increased due to the significant enhancement in droplet concentration.

Research Organization:
Lockheed Martin Corporation, Schenectady, NY 12301 (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC12-00SN39357
OSTI ID:
821307
Report Number(s):
LM-00K074
Country of Publication:
United States
Language:
English

Similar Records

Experimental study of dispersed droplets in high-pressure annular flows
Journal Article · Sun Oct 31 23:00:00 EST 1999 · Journal of Heat Transfer · OSTI ID:20005630

High pressure annular two-phase flow in a narrow duct. Part 1: Local measurements in the droplet field, and Part 2: Three-field modeling
Technical Report · Thu Jul 01 00:00:00 EDT 1999 · OSTI ID:353192

Hot-film anemometer measurements in adiabatic two-phase flow through a vertical duct
Technical Report · Sun Jun 01 00:00:00 EDT 1997 · OSTI ID:350943