In previously published analyses of the 41-building 1994-1996 USEPA Building Assessment Survey and Evaluation (BASE) dataset, higher workday time-averaged indoor minus outdoor CO{sub 2} concentrations (dCO{sub 2}) were associated with increased prevalence of certain mucous membrane and lower respiratory sick building syndrome (SBS) symptoms, even at peak dCO{sub 2} concentrations below 1,000 ppm. For this paper, similar analyses were performed using the larger 100-building 1994-1998 BASE dataset. Multivariate logistic regression analyses quantified the associations between dCO{sub 2} and the SBS symptoms, adjusting for age, sex, smoking status, presence of carpet in workspace, thermal exposure, relative humidity, and a marker for entrained automobile exhaust. Adjusted dCO{sub 2} prevalence odds ratios for sore throat and wheeze were 1.17 and 1.20 per 100-ppm increase in dCO{sub 2} (p <0.05), respectively. These new analyses generally support our prior findings. Regional differences in climate, building design, and operation may account for some of the differences observed in analyses of the two datasets.
- Research Organization:
- Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (US)
- Sponsoring Organization:
- USDOE Assistant Secretary for Energy Efficiency and Renewable Energy. Building Technologies Program; Environmental Protection Agency (US)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 820782
- Report Number(s):
- LBNL--49584
- Country of Publication:
- United States
- Language:
- English
Similar Records
Associations of indoor carbon dioxide concentrations, VOCS, environmental susceptibilities with mucous membrane and lower respiratory sick building syndrome symptoms in the BASE study: Analyses of the 100 building dataset
Associations of indoor carbon dioxide concentrations and environmental susceptibilities with mucous membrane and lower respiratory building related symptoms in the BASE study: Analyses of the 100 building dataset
Quantitative relationship of sick building syndrome symptoms with ventilation rates
Technical Report
·
Tue Oct 01 00:00:00 EDT 2002
·
OSTI ID:806126
Associations of indoor carbon dioxide concentrations and environmental susceptibilities with mucous membrane and lower respiratory building related symptoms in the BASE study: Analyses of the 100 building dataset
Journal Article
·
Mon Sep 01 00:00:00 EDT 2003
· Indoor Air Special Edition
·
OSTI ID:840385
Quantitative relationship of sick building syndrome symptoms with ventilation rates
Journal Article
·
Wed Dec 31 23:00:00 EST 2008
· Indoor Air
·
OSTI ID:962730