Control Software Components for the CEBAF Synchrotron Light Interferometer Project
Conference
·
OSTI ID:816457
The first synchrotron light interferometer (SLI) has been built at Jefferson Lab. The SLI is a valuable beam diagnostic instrument for the CEBAF accelerator. It is a non-invasive, multi-element measurement device consisting of a CCD video camera, a video image processing system, and a set of stepper-motors to adjust the positions of optics parts and diffraction slits. The main functions of the SLI elements are automated with the use of new distributed control software. The paper describes the structure of this software and its performance.
- Research Organization:
- Thomas Jefferson National Accelerator Facility, Newport News, VA (US)
- Sponsoring Organization:
- USDOE Office of Energy Research (ER) (US)
- DOE Contract Number:
- AC05-84ER40150
- OSTI ID:
- 816457
- Report Number(s):
- JLAB-ACO-03-185; DOE/ER/40150-2555
- Country of Publication:
- United States
- Language:
- English