Technical evaluation of the adequacy of station electric distribution system voltages for the Rancho Seco Nuclear Generating Station, Unit No. 1: selected issues program (Docket No. 50-312)
This report documents the technical evaluation of the adequacy of the station electric distribution system voltages for the Rancho Seco Nuclear Generation Station, Unit No. 1. The evaluation is to determine if the onsite distribution system, in conjunction with the offsite power sources, has sufficient capacity to automatically start and operate all Class 1E loads within the equipment voltage ratings under certain conditions established by the Nuclear Regulatory Commission. The licensee demonstrates with the analysis that with certain modifications the guidelines and requirements of the NRC will be met.
- Research Organization:
- Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 8143424
- Report Number(s):
- UCID-19113; ON: DE82005461
- Country of Publication:
- United States
- Language:
- English
Similar Records
Technical evaluation of the adequacy of station electric distribution system voltages for the R. E. Ginna Nuclear Power Station, Unit 1: selected issues program (Docket No. 50-244)
Technical-evaluation report on the adequacy of station electric-distribution-system voltages for the Prairie Island Nuclear Generating Plant, Units 1 and 2. (Docket Nos. 50-282, 50-306)
Technical evaluation of the adequacy of station electric distribution systems voltages for the Calvert Cliffs Nuclear Power Plant, Units 1 and 2. Docket Nos. 50-317, 50-318
Technical Report
·
Thu Nov 05 00:00:00 EST 1981
·
OSTI ID:8143424
Technical-evaluation report on the adequacy of station electric-distribution-system voltages for the Prairie Island Nuclear Generating Plant, Units 1 and 2. (Docket Nos. 50-282, 50-306)
Technical Report
·
Fri Sep 17 00:00:00 EDT 1982
·
OSTI ID:8143424
Technical evaluation of the adequacy of station electric distribution systems voltages for the Calvert Cliffs Nuclear Power Plant, Units 1 and 2. Docket Nos. 50-317, 50-318
Technical Report
·
Fri Apr 09 00:00:00 EST 1982
·
OSTI ID:8143424
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
RANCHO SECO-1 REACTOR
ELECTRICAL EQUIPMENT
POWER SUPPLIES
PERFORMANCE
RELIABILITY
ELECTRONIC EQUIPMENT
ENRICHED URANIUM REACTORS
EQUIPMENT
POWER REACTORS
PWR TYPE REACTORS
REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
RANCHO SECO-1 REACTOR
ELECTRICAL EQUIPMENT
POWER SUPPLIES
PERFORMANCE
RELIABILITY
ELECTRONIC EQUIPMENT
ENRICHED URANIUM REACTORS
EQUIPMENT
POWER REACTORS
PWR TYPE REACTORS
REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled