Status of Digital Orbit Feedback for SPEAR

Technical Report ·
DOI:https://doi.org/10.2172/813197· OSTI ID:813197
The present global orbit feedback system for SPEAR can adjust the electron beam position with a cycle time of 5 s. In addition, 50 Hz analog local servos stabilize the vertical photon beam position at monitors situated in the ten SSRL beamlines. The global and local systems will soon be merged into a single unified system operating from a dedicated DSP board. The goal is to acquire orbits, process the data, and correct beam position in a 1-2 ms interval to achieve a 30-50 Hz closed-loop bandwidth.
Research Organization:
Stanford Linear Accelerator Center, Menlo Park, CA (US)
Sponsoring Organization:
USDOE Office of Science (US)
DOE Contract Number:
AC03-76SF00515;
OSTI ID:
813197
Report Number(s):
SLAC-PUB-9910
Country of Publication:
United States
Language:
English

Similar Records

Closed orbit feedback with digital signal processing
Technical Report · Mon Aug 01 00:00:00 EDT 1994 · OSTI ID:10171970

Digital closed orbit feedback system for the advanced photon source storage ring
Conference · Sat Dec 30 23:00:00 EST 1995 · OSTI ID:188943

Digital closed orbit feedback system for the Advanced Photon Source storage ring